SolarCore P1
VM350WE-P1 · VM400WE-P1 · VM450WE-P1 · VM500WE-P1
- 350–500 VA
- 1 MPPT
- IP67
12-year limited warranty (Europe) — See warranty periods
Four modules on one unit for rooftop arrays — fewer units and connections per kW, each module still on its own MPPT.
SolarSolarCore P4
* With good signal, a working network and a normal device connection.
Up to 2,250 W per unit, MPPT efficiency up to 99.8%.
Added in the VIP Cloud app over 2.4 GHz Wi-Fi.
* With good signal, a working network and a normal device connection.
Rooftop and garden arrays, with fewer AC connections per kW.
IP67 metal housing, fanless, galvanically isolated.
Keep module Voc below 60 V at the lowest expected site temperature — Voc rises in the cold.
SolarCore P4 is made for rooftop and garden arrays, usually on an AC trunk cable installed by a qualified electrician. In countries with higher plug-in limits it can also connect by plug.
One SolarCore P4 takes four modules, each on its own MPPT. Its AC cable joins the trunk cable through a T-connector and runs via an AC box to the distribution board.
Illustration simplified. Systems on an AC trunk cable are installed by a qualified electrician.
Power the microinverter, open the VIP Cloud app and add it over Wi-Fi. It joins the home network directly — no gateway, no separate data logger — and starts reporting live data in about 10 seconds*.
* With good signal, a working network and a normal device connection.


Up to four modules per unit on one AC trunk cable

Installed by a qualified electrician
SolarCore P4 usually connects to the distribution board through an AC trunk cable, installed by a qualified electrician. Where national rules permit higher plug-in limits, it can also be connected by plug.
Playing a video loads it from YouTube (Google), which then receives your IP address. Privacy policy
| Model | VM2000W-P4 | VM2100W-P4 | VM2250W-P4 |
|---|---|---|---|
| Rated output (VA) | 2,000 | 2,100 | 2,250 |
| Rated output current (A) | 8.8 | 9.2 | 9.9 |
| Compatible module power (Wp) | 400–670 | 400–670 | 400–700 |
| Peak efficiency | 96.6% | 96.6% | 96.5% |
| MPPT efficiency | up to 99.8% | ||
| Max. units per branch (4 / 6 mm²) | 3 / 4 | ||
| PV input (DC) | |||
| MPPTs / inputs per MPPT | 4 / 1 | ||
| Operating / MPPT voltage range | 14–61 V / 20–60 V | ||
| Start-up voltage | 18 V | ||
| Max. input voltage | 61 V | ||
| Max. input / short-circuit current per MPPT | 18 A / 25 A | ||
| AC output | |||
| Nominal voltage (range) | 220–240 V (180–275 V) | ||
| Nominal frequency | 50 / 60 Hz | ||
| Max. output overcurrent / fault current | 13.9 A / 13.9 A | ||
| Power factor / THD | > 0.99 (default), adjustable / < 3% | ||
| Night-time power consumption | < 50 mW | ||
| General | |||
| Dimensions (W × H × D) / weight | 347 × 260 × 36.5 mm / 5.1 kg | ||
| Housing / ingress protection | Metal / IP67 (NEMA 6), outdoor | ||
| Operating ambient temperature | −40 to 65 °C (derating at high temperatures) | ||
| Relative humidity / max. altitude | 0–100%, non-condensing / 2,000 m | ||
| Cooling / isolation | Natural convection, fanless / galvanically isolated | ||
| Communication / monitoring | Wi-Fi (2.4 GHz) / VIP Cloud | ||
| Zero export control | Via EnergyPilot local EMS controller (optional) | ||
A single plug-in unit up to 800 W (such as SolarCore VM800WE-P2 or SolarKit) and PowerCube VA800D may be connected by the owner where local rules allow; where national rules permit higher plug-in limits, SolarCore P4 can also be connected by plug. Other SolarCore systems on an AC trunk cable, PowerCube VA2000D and above, VB5000D packs, SolarHub, ChargeFlow and EnergyPilot are installed by a qualified electrician.