Microinverter · 1 MPPT

SolarCore P1

A compact single-module microinverter for rooftops, fences, sheds and small balconies. Every module gets its own MPPT, and Wi-Fi pairing in the VIP Cloud app takes about 10 seconds*.

VM350WE-P1VM400WE-P1VM450WE-P1VM500WE-P1
SolarCore P1 solar microinverter: VM350WE-P1, VM400WE-P1, VM450WE-P1, VM500WE-P1SolarSolarCore P1
SolarCore P1 solar microinverter: VM350WE-P1, VM400WE-P1, VM450WE-P1, VM500WE-P1
350–500 VARated output
1 MPPTOne module per unit
~10 sWi-Fi pairing*
IP67Metal housing, −40 to 65 °C

* With good signal, a working network and a normal device connection.

Highlights

Small unit, simple set-up.

  • Wi-Fi pairing in about 10 seconds*

    Added in the VIP Cloud app over 2.4 GHz Wi-Fi — no gateway needed.

    * With good signal, a working network and a normal device connection.

  • Module-level MPPT

    Every module on its own MPPT, with MPPT efficiency up to 99.8%.

  • Plug-in to rooftop

    Balcony plug-in, garden or rooftop — one unit per module.

    Plug-in only where local rules allow; permitted power limits differ by country.

  • −40 to 65 °C

    IP67 (NEMA 6) metal housing, fanless, galvanically isolated.

Keep module Voc below 60 V at the lowest expected site temperature — Voc rises in the cold.

How it grows

Start with one module. Grow to a whole roof.

The same microinverter covers a plug-in balcony system, a rooftop array and a smart home system with storage.

HomeDistribution boardGridSolarCore P1Household socket≤ 800 W plug-inSolar moduleSolarCore P1T-connectorAC trunk cableAC boxInstalled by an electricianOne smart systemEnergyPilotCTPowerCube
  1. One module, one household socket.

    A module with its own SolarCore P1 connects to a household socket with a plug-in AC cable. Plug-in use is limited to 800 W and allowed only where local rules permit.

    • 1 module
    • SolarCore P1
    • Plug-in AC cable
    • Household socket

Illustration simplified. Plug-in connection only up to 800 W and only where local rules allow. Systems on an AC trunk cable are installed by a qualified electrician.

Network set-up

Paired in about 10 seconds*.

Power the microinverter, open the VIP Cloud app and add it over Wi-Fi. It joins the home network directly — no gateway, no separate data logger — and starts reporting live data in about 10 seconds*.

  • Direct 2.4 GHz Wi-Fi, no extra hardware
  • Guided pairing in the VIP Cloud app
  • Live output and yield history from the first minute

* With good signal, a working network and a normal device connection.

Paired in about 10 seconds*.
Where it fits

From plug-in balcony to rooftop.

Balcony and plug-in
Balcony plug-in

Balcony and plug-in

One unit with its own module

Gardens, fences and sheds
Garden

Gardens, fences and sheds

Fences, sheds and carports

Rooftop arrays
Rooftop

Rooftop arrays

Several units on one AC trunk cable

Plug-in only where local rules allow; permitted power limits differ by country.

Watch

Product overview.

SolarCore P1 — product overview

Playing a video loads it from YouTube (Google), which then receives your IP address. Privacy policy

Specifications

SolarCore VM-P1

ModelVM350WE-P1VM400WE-P1VM450WE-P1VM500WE-P1
Rated output (VA)350400450500
Rated output current (A)1.691.922.182.41
Compatible module power (Wp)280–470320–540360–600400–670
Peak efficiency96.8%96.8%96.6%96.6%
MPPT efficiencyup to 99.8%
Max. units per branch (2.5 / 4 mm²)15 / 2113 / 1812 / 1611 / 14
PV input (DC)
MPPTs / inputs per MPPT1 / 1
Operating / MPPT voltage range14–63 V / 16–60 V
Start-up voltage18 V
Max. input voltage63 V
Max. input / short-circuit current per MPPT18 A / 25 A
AC output
Nominal voltage (range)230 / 240 V (180–275 V)
Nominal frequency50 / 60 Hz
Max. output overcurrent / fault current3.6 A / 3.6 A
Power factor / THD> 0.99 (default), adjustable / < 3%
Night-time power consumption< 50 mW
General
Dimensions (W × H × D) / weight181 × 203 × 32 mm / 1.75 kg
Housing / ingress protectionMetal / IP67 (NEMA 6), outdoor
Operating ambient temperature−40 to 65 °C (derating at high temperatures)
Relative humidity / max. altitude0–100%, non-condensing / 2,000 m
Cooling / isolationNatural convection, fanless / galvanically isolated
Communication / monitoringWi-Fi (2.4 GHz) / VIP Cloud
Zero export controlVia EnergyPilot local EMS controller (optional)
  1. Keep module Voc below 60 V at the lowest expected site temperature — Voc rises in the cold.
  2. Units per branch depend on the AC cable cross-section; always follow local requirements.
  3. Values measured in the VaySunic laboratory under specific test conditions; they are typical values, not warranted values.
Warranty & documents

Covered, and documented.

12years

12-year limited warranty (Europe)

  • Your statutory rights are not affected.
See warranty periods

Datasheet values are typical lab values and are not warranted values.

Get in touch

Let’s plan your next project.

Distribution, installation or your own brand — tell us what you need and the right person will reply.